Type:
Bug
-
Status: Closed
-
Priority:
Critical
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: None
-
Component/s: None
-
Labels:None
-
Environment:QA
-
Bug Type:Functional
-
Bug Severity:Critical
-
Level:Partner
-
Module:BenAdmin - Export
-
Reported by:Harbinger
-
Item State:Production Complete - Closed
Browser Name: Chrome, IE.11
Test Environment Name: LB
User details : verified with SA
Steps to repro :-
1.Login to workterra.
2.Click on Import/Export
3.Click on OE dashboard.
4.Click on Column sequencing
5.Change sequence of OE start date and OE end date.
Actual result :- OE start date and end date is getting editable after changing sequence
Attached Screenshot :-
Before Sequence change
After Sequence change
Expected Result :- OE start date and end date should not get editable after changing sequence
CC-Aniruddha DevHrishikesh DeshpandeRakesh RoyGaurav SodaniVinayak Kulkarni
- is caused by
-
WT-10490 Open enrollment dashboard - column sequencing
-
- Closed
-
Field | Original Value | New Value |
---|---|---|
Remaining Estimate | 0h [ 0 ] | |
Time Spent | 1.5h [ 5400 ] | |
Worklog Id | 71469 [ 71469 ] |
Status | Open [ 1 ] | In Development [ 10007 ] |
Assignee | Ganesh Sadawarte [ ganesh.sadawarte ] | Swapnil Eksambekar [ swapnil.eksambekar ] |
Status | In Development [ 10007 ] | Local Testing [ 10200 ] |
Item State | Parent values: LB QA(10201)Level 1 values: Ready for Stage(10213) | |
Original Estimate | 0h [ 0 ] |
Time Spent | 1.5h [ 5400 ] | 2.5h [ 9000 ] |
Worklog Id | 73544 [ 73544 ] |
Item State | Parent values: LB QA(10201)Level 1 values: Ready for Stage(10213) | Parent values: Stage QA(10202)Level 1 values: Stage Deployed(11602) |
Item State | Parent values: Stage QA(10202)Level 1 values: Stage Deployed(11602) | Parent values: Stage QA(10202)Level 1 values: In Testing(10214) |
Status | Local Testing [ 10200 ] | Stage Testing [ 10201 ] |
Item State | Parent values: Stage QA(10202)Level 1 values: In Testing(10214) | Parent values: Stage QA(10202)Level 1 values: Ready for Production(10217) |
Time Spent | 2.5h [ 9000 ] | 2.7h [ 9720 ] |
Worklog Id | 77835 [ 77835 ] |
Status | Stage Testing [ 10201 ] | Production Testing [ 10202 ] |
Resolution | Fixed [ 1 ] | |
Status | Production Testing [ 10202 ] | Production Complete [ 10028 ] |
Item State | Parent values: Stage QA(10202)Level 1 values: Ready for Production(10217) | Parent values: Production Complete(10222)Level 1 values: Closed(10223) |
Status | Production Complete [ 10028 ] | Closed [ 6 ] |
Environment_New | LB [ 18444 ] |
Transition | Time In Source Status | Execution Times |
---|
|
1d 7h 13m | 1 |
|
6d 20h 1m | 1 |
|
16d 23h 42m | 1 |
|
5d 18h 59m | 1 |
|
17s | 1 |
|
1d 2h | 1 |
Concern: Open enrollment dashboard - column sequencing - OE start date and end date is getting editable after changing sequence
Cause: As we change our data-table implementation, into this disable class was not set properly.
Correction: We have handle this with code fix.
CC-Vinayak Kulkarni