Type:
Bug
-
Status: Closed
-
Priority:
Medium
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: None
-
Component/s: ACA
-
Labels:None
-
Environment:QA
-
Module:ACA
-
Reported by:Harbinger
Company - ACAAutomation
SSN - 300000103
Report Name - 1095C 26Oct16 1228
Pr-requisite-
1.Add EE SSN - 300000103 with WT-2605,WT-2605
2.Move employee to class WT-2605A,WT-2605A effective date – 02/01/2016
3.Update class change date – 03/01/2016
Step -
1.Login to application and select company
2.Navigate to Employee Administration > Search employee > Enter SSN
3.Click on employee name ( hyperlink )
4.Navigate Employee > Employee Management > Change class
5.Select Employee status and enter date 02/01/2016
6.Click on save
7.Run 1095C
8.Change class change to 03/01/2016 and save
9.Now again re-run the 1095C
Actual - Terminated code reflected from Feb 16
Expected - Terminated code should reflected from April 16
- is caused by
-
WT-2605 Employee status, classes or date changes need to be tracked with more accuracy.
-
- Closed
-
Mahendra Mungase
This is not an issue.
Please refer to the screen shot :
Employee division was changed to
WT-2605A with effective date 2/1/2016.There are no further changes to employee's classes even if only effective date is changed.
As EE's class was changed from Feb and as this report is for only one class, codes shown are proper.
CC: Nandkumar Prabhakar Karlekar,Sachin Hingole