Type:
Change Request
-
Status: Closed
-
Priority:
Medium
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: None
-
Component/s: ACA
-
Labels:None
-
Module:ACA
-
Reported by:Harbinger
-
Item State:Production Complete - Closed
1.Login to LB company [ACA Automation].
2.Navigate to Home>>Company Home>>BenAdmin Home>>BenAdmin Company Home>>ACA>>IRS Submission
3.Create a valid IRS submission.
4.Login to IRS site with valid credentials.
5.Upload Manifest & Request files.
6.Click on Transmit.
7.
Actual: Received a Receipt ID 'AATS1095C-17-00002604' is not accepted by Workterra system.
Expected: Workterra system should accept Receipt ID generated by IRS system.
Hi Smita Pawar,Sachin Hingole
FYI,
As per discussion with Nandkumar Prabhakar Karlekar , if submission type is Test i.e T then we are just providing max length of 21 to Receipt ID ( as Receipt ID mentioned for AATS scenario is AATS1095C-16-00001234) and no more validations will be fired.
Note - For submission type Production i.e P the validations will be the same as of now.
CC - Revansiddha Gaur Ramya Tantry