Uploaded image for project: 'WORKTERRA'
  1. WORKTERRA
  2. WT-7495

Eligibility Check routine is getting failed

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Production Complete
    • Priority: High
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: None
    • Component/s: None
    • Labels:
      None
    • Environment:
      QA
    • Bug Severity:
      Medium
    • Module:
      BenAdmin - Import
    • Reported by:
      Harbinger
    • Item State:
      Production Complete - Closed
    • Code Reviewed By:
      Jaideep Vinchurkar

      Description

      Eligibility Check Routine is failed refer below error log:

      ErrorID : 0
      ErrorSource : ControllerAppTier.Save->WORKTERRAControllerAppTier.Save->ExecuteImportDTS.GetImportExportTemplateInformationBackEndRoutine
      ErrorMessage: Object reference not set to an instance of an object.

        Attachments

          Issue Links

            Activity

              People

              Assignee:
              jayshree.nagpure Jayshree Nagpure (Inactive)
              Reporter:
              rashmita.dudhe Rashmita Dudhe (Inactive)
              Developer:
              Ankur Deshpande (Inactive)
              Votes:
              0 Vote for this issue
              Watchers:
              3 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved:

                  Time Tracking

                  Estimated:
                  Original Estimate - 1h Original Estimate - 1h
                  1h
                  Remaining:
                  Remaining Estimate - 0h
                  0h
                  Logged:
                  Time Spent - 9.5h
                  9.5h